Appendix 1
Sampling and test frequency for the application year
Type of plant |
Criterion |
Annual input/output |
Test frequency |
Type 1: Treatment plants for waste or for animal by-products |
5.1 — Limits for heavy metals 5.5 — Limits for E. coli and Salmonella spp. 6 — Stability 7 — Physical contaminants 8 — Organic matter and dry matter 9 — Viable seeds and plant propagules 10 — Plant response 11 — Growing media features |
Input (t) ≤ 3 000 |
1 every 1 000 tonnes input material rounded to the next integer |
3 000 < input (t) ≤ 20 000 |
4 (one sample every season) |
||
Input (t) > 20 000 |
number of analyses per year = amount of annual input material (in tonnes)/10 000 tonne + 1 Minimum 4 and maximum 12 |
||
5.2 — PAH |
Input (t) ≤ 3 000 |
1 |
|
3 000 < input (t) ≤ 10 000 |
2 |
||
10 000 < input (t) ≤ 20 000 |
3 |
||
20 000 < input (t) ≤ 40 000 |
4 |
||
40 000 < input (t) ≤ 60 000 |
5 |
||
60 000 < input (t) ≤ 80 000 |
6 |
||
80 000 < input (t) ≤ 100 000 |
7 |
||
100 000 < input (t) ≤ 120 000 |
8 |
||
120 000 < input (t) ≤ 140 000 |
9 |
||
140 000 < input (t) ≤ 160 000 |
10 |
||
160 000 < input (t) ≤ 180 000 |
11 |
||
Input (t) > 180 000 |
12 |
||
Type 2: Product manufacture plants using materials from Type 1 plants |
5.1 — Limits for heavy metals 5.5 — Limits for E. coli and Salmonella spp. 6 — Stability 7 — Physical contaminants 8 — Organic matter and dry matter 9 — Viable seeds and plant propagules 10 — Plant response 11 — Growing media features |
Output (m3) ≤ 5 000 |
Representative combined samples from 2 batches according EN 12579 (1) |
Output (m3) > 5 000 |
Representative combined samples from 4 batches according EN 12579 |
||
5.2 — PAH |
Output (m3) ≤ 5 000 |
Representative combined sample(s) from 1 batch according EN 12579 |
|
Output (m3) > 5 000 |
Representative combined samples from 2 batches according EN 12579 |
||
Type 3: Product manufacture plants NOT using materials derived from waste or from animal by-products |
5.1 — Limits for heavy metals 5.5 — Limits for E. coli and Salmonella spp. 6 — Stability 7 — Physical contaminants 8 — Organic matter and dry matter 9 — Viable seeds and plant propagules 10 — Plant response 11 — Growing media features |
Output (m3) ≤ 5 000 |
Representative combined sample(s) from 1 batch according EN 12579 |
Output (m3) > 5 000 |
Representative combined samples from 2 batches according EN 12579 |
||
5.2 — PAH |
Regardless the input/output |
Representative combined sample(s) from 1 batch according EN 12579 |
|
(1) EN 12579 Soil improvers and growing media. Sampling. |